Fix it now
The C runtime stopped the process rather than run in a state it does not trust. Microsoft’s current runtime error list documents R6002, R6025 and R6030 but no longer publishes anything for R6034, so treat that one by what you can observe: which copy of the runtime the application is loading, and where it came from.
where msvcr90.dll
where msvcr100.dll
where msvcp100.dll
tasklist /m msvcr*
- Look in the application’s own folder for files named
msvcr*.dll,msvcp*.dllormfc*.dll. A copy sitting beside the executable that the vendor’s installer did not put there is the usual suspect. - Rename any such file to add a
.bakextension rather than deleting it, then start the application again. - If the folder is clean, read the
whereoutput. A hit in a folder belonging to unrelated software – a printer utility, a database client, an old development tool – is the next thing to move off the search path. - Install the Visual C++ redistributable the application was built against, in the matching architecture, and restart the machine.
Rename rather than delete. Some vendors ship a deliberately modified runtime and the application will not start without it, in which case the vendor’s own updater is the right route.
If the application starts and stays up, you are done. If the code is R6025, R6030 or R6002, the next section explains why those are different problems with different owners.
Why it happens
The generation of Microsoft C runtimes that shipped before the universal CRT were deployed as side-by-side assemblies. Rather than a file in a system folder, they live in the component store and an application asks for one by declaring a dependency in its manifest. The loader then binds the correct version. That design existed to end the era of applications overwriting each other’s runtime files.
R6034 belongs to that world. Microsoft’s current list of C runtime errors runs from R6002 to R6035 and does not include it, and no Microsoft documentation page carries its message text, so anything you read about the precise mechanism – including here – is not something the vendor publishes today. What is observable is straightforward enough: the message appears when an application is using a copy of an old runtime that did not come through the normal resolution, and it stops appearing when that copy is out of the way.
The neighbours are documented, and they are not variations on the same theme. R6025 is published as “pure virtual function call”, which is a defect in the application’s own code. R6030 is “CRT not initialized”, which means code ran before the runtime had finished starting – typically from a DLL doing too much work in its entry point. R6002 is “floating-point support not loaded”. None of the three is fixed by moving a DLL around.
One practical consequence is worth stating plainly. Applications built against the universal CRT introduced with the 2015 generation do not use the side-by-side mechanism this error belongs to. Seeing R6034 at all tells you an older component is still in the chain, and in a modern estate that is more often a plug-in or an add-in than the main program.
A loose runtime DLL sits beside the executable
You have this one if The application folder contains a file such as msvcr90.dll that the vendor’s installer did not create – often left by a plug-in or an update tool.
- Close the application completely, including any tray component.
- Rename the file by appending
.bakso you can restore it if you were wrong. - Start the application. If it now runs, install the matching Visual C++ redistributable so a properly registered copy serves it.
- If it does not run, restore the renamed file before moving on.
A third-party folder on PATH is exporting a runtime
You have this one if The application folder is clean, but where msvcr90.dll returns a hit in a folder belonging to unrelated software.
- Run
wherefor each runtime name and record every path returned. - Open the system environment editor and inspect PATH, both the system and the user variable.
- Remove the offending directory if nothing depends on it, or move it below the system entries so it is searched later.
- Sign out and back in, then retest. PATH is read at process start, so a shell that is already open keeps the old value.
The correct redistributable was never installed
You have this one if No stray copies exist anywhere, and the application is a vendor build that has always failed on this machine.
- Check the vendor’s system requirements for the runtime generation the application needs.
- Install that redistributable in the same architecture as the application.
- Install both architectures if the application loads 32-bit plug-ins into a 64-bit host or the reverse.
- Reboot and retest.
R6025, a pure virtual function call
You have this one if The code is R6025 rather than R6034, and it appears at a repeatable point such as closing a document or exiting the program.
- Update the application to the newest build the vendor offers. This is a coding defect and only the vendor can fix it.
- Note the exact sequence that triggers it and send that to their support channel.
- Check whether a plug-in is involved by starting the application with add-ins disabled if it offers that option.
Do not attempt to patch the runtime to suppress it. Replacing runtime files to hide a crash produces a machine nobody can support.
R6030 or R6002, with several applications affected
You have this one if The code is one of those two and more than one unrelated application is failing.
- Repair every Visual C++ redistributable entry from Settings, Apps, Installed apps, Modify, Repair.
- Run
sfc /scannowfrom an elevated Command Prompt. - Follow with
DISM /Online /Cleanup-Image /RestoreHealthif sfc reports files it could not repair. - Reboot and retest.
Full reference
What Microsoft publishes, and what it does not
| Code | Published message | Whose problem |
|---|---|---|
| R6002 | floating-point support not loaded | The application’s build |
| R6025 | pure virtual function call | A defect in the application’s own code |
| R6030 | CRT not initialized | Code running before the runtime finished starting, usually from a DLL entry point |
| R6031 | Attempt to initialize the CRT more than once. This indicates a bug in your application. | The application |
| R6033 | Attempt to use MSIL code from this assembly during native code initialization | The application |
| R6034 | Not published by Microsoft in its current runtime error list | Diagnose by observation |
The absence of R6034 from Microsoft’s current list is a fact worth carrying into any conversation about it. A great deal is written about this error, and none of it traces back to a page the vendor maintains. That does not make the error unreal – it makes the diagnosis empirical, which is why the steps here are about finding and moving copies of files rather than reasoning from a published mechanism.
Diagnostic commands
| Command | What it does |
|---|---|
where msvcr90.dll |
Lists every copy of that runtime on the search path in resolution order |
tasklist /m msvcr* |
Shows which running processes have a runtime of that family loaded |
sxstrace trace -logfile:C:\temp\sxs.etl |
Records side-by-side resolution while you reproduce the failure; stop it at the prompt, not with Ctrl+C |
sfc /scannow |
Verifies protected system files, including system-installed runtime components |
tasklist /m is the underused one. Run it while the application is up, or while a related process is, and it shows which module is actually loaded rather than which one you expect. On a machine with several copies on disk, that is the difference between a guess and an answer.
Working out which family an application needs
- The vendor’s system requirements are the first source and usually the only one you need.
- Failing that, the file names give it away: the runtime DLLs the application ships or asks for carry the generation in their names.
- Microsoft’s current guidance is that Visual Studio 2017 and later share the same redistributable files, and that the installed Redistributable must be the same version as, or later than, the build tools used.
- Older families are separate products. Installing the newest package does nothing for an application that needs one of them.
- Architecture is separate again: X86, X64 and ARM64 are published separately, and the X64 package contains both ARM64 and X64 binaries.
When only one user is affected
PATH exists as both a system variable and a per-user one, and the per-user entries are appended to the system ones for that account only. A runtime copy in a folder listed only in one user’s PATH produces a failure that follows that person between applications and does not reproduce for anyone else. The system environment editor shows both lists; compare them before concluding the profile is corrupt.
Things not to do
- Do not copy a runtime DLL from another machine into the application folder. That is the arrangement that produces this error, not the cure for it.
- Do not delete runtime files from system folders. If one is genuinely wrong, repair or reinstall the redistributable that owns it.
- Do not disable the application’s own updater to stop it replacing a file. It is usually replacing it for a reason.
- Do not chase R6025 with runtime work. It is a null call to a pure virtual function inside the application and no environment change fixes it.
- Do not leave a
.bakfile in place indefinitely. Once the application works, decide whether the file should be there and remove it or restore it properly.
Every code this article covers
| Code | What it points at | Source |
|---|---|---|
R6034 |
Reported by the C runtime when it will not continue in the state it was loaded in. Microsoft’s current runtime error list does not include it, so it is described here by what can be observed rather than by a published meaning | not published by the vendor |
R6025 |
pure virtual function call – a defect in the application’s own code | Microsoft Learn |
R6030 |
CRT not initialized – code ran before the runtime had finished initialising | Microsoft Learn |
R6002 |
floating-point support not loaded | Microsoft Learn |
Confirm the fix worked
- Start the application and confirm it reaches its normal interface with no runtime dialog.
- Run
where msvcr90.dllagain and confirm the only results are in system directories. - Run
tasklist /m msvcr*while the application is running and confirm it has loaded the copy you intended. - Exercise the action that previously triggered the error, such as opening a document or closing the program.
- Restart the machine and repeat the test once, so you know PATH and any service-launched instances are also clean.
Questions people ask about this
Is there anything to buy to fix R6034?
No. Every Visual C++ redistributable is a free download from Microsoft, and everything else here is a rename or a built-in repair command. A tool offering to sell you a runtime fix is selling you something you already have.
Does Microsoft document R6034?
Not in its current C runtime error list, which runs from R6002 to R6035 and omits it. Its neighbours R6002, R6025, R6030, R6031 and R6033 are all published. That is worth knowing because most of what is written about R6034 is not traceable to the vendor.
Can I just copy a working msvcr90.dll from another PC?
No. That is precisely the arrangement that produces this error. The runtime is meant to be installed by its own installer rather than placed as a loose file.
Why does the error only appear for one user on a shared machine?
PATH can be set per user as well as system-wide, and per-user application folders differ. Check the user PATH in the environment editor and look for runtime copies under that profile.
Do modern applications still hit R6034?
Rarely. Applications built against the universal CRT introduced with the 2015 generation do not use the side-by-side mechanism this error belongs to. Seeing it usually means an older component is still in the chain, often a plug-in rather than the main program.